  • undefined

Single-use laryngeal mask airway catheter

Single-use laryngeal mask airway tubes are classified based on structure and material into: Type A laryngeal mask (A1 type made of silicone, A2 type made of PVC), Type B laryngeal mask (B1 type made of silicone, B2 type made of PVC), Type C laryngeal mask (C1 type made of silicone, C2 type made of PVC), Type D laryngeal mask (D1 type made of silicone, D2 type made of PVC), and Type E laryngeal mask (E1 made of silicone + camera); laryngeal mask airway tubes are available in eight specifications based on size: 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, and 6.0. The products are sterilized using ethylene oxide and should be sterile.

  • Commodity name: Single-use laryngeal mask airway catheter

Key words:

Consulting>>
  • Description
  • Performance structure and composition

    Disposable laryngeal mask airway tubes are classified into different types based on structure and material: Type A laryngeal mask (A1 type is silicone material, A2 type is PVC material), Type B laryngeal mask (B1 type is silicone material, B2 type is PVC material), Type C laryngeal mask (C1 type is silicone material, C2 type is PVC material), Type D laryngeal mask (D1 type is silicone material, D2 type is PVC material), Type E laryngeal mask (E1 is silicone material + camera); laryngeal mask airway tubes are divided into eight specifications based on size: 1.0, 1.5, 2.0, 2.5, 3.0, 4.0, 5.0, 6.0. The product is sterilized with ethylene oxide and should be sterile.

     Scope of application

    Establishing a temporary artificial airway clinically

    Specifications and models

    Type A (KCA11-1.0, KCA11-1.5, KCA11-2.0, KCA1l-2.5, KCA11-3.0, KCA11-4.0, KCA11-5.0, KCA11-6.0

    KCA12-1.0, KCA12-1.5, KCA12-2.0, KCA12-2.5, KCA12-3.0, KCA12-4.0, KCA12-5.0, KCA12-6.0

    KCA21-1.0, KCA21-1.5, KCA21-2.0, KCA21-2.5, KCA21-3.0, KCA21-4.0, KCA21-5.0, KCA21-6.0

    KCA22-1.0, KCA22-1.5, KCA22-2.0, KCA22-2.5, KCA22-3.0, KCA22-4.0, KCA22-5.0, KCA22-6.0)

    Type B (KCB11-1.0, KCB11-1.5, KCB11-2.0, KCB11-2.5, KCB11-3.0, KCB11-4.0, KCB11-5.0, KCB11-6.0

    KCB12-1.0, KCB12-1.5, KCB12-2.0, KCB12-2.5, KCB12-3.0, KCB12-4.0, KCB12-5.0, KCB12-6.0

    KCB21-1.0, KCB21-1.5, KCB21-2.0, KCB21-2.5, KCB21-3.0, KCB21-4.0, KCB21-5.0, KCB21-6.0 KCB22-1.0, KCB22-1.5, KCB22-2.0, KCB22-2.5, KCB22-3.0, KCB22-4.0, KCB22-5.0, KCB22-6.0)

    Type C (KCC11-1.0, KCC11-1.5, KCC11-2.0, KCC11-2.5, KCC11-3.0, KCC11-4.0, KCC11-5.0, KCC11-6.0

    KCC12-1.0, KCC12-1.5, KCC12-2.0, KCC12-2.5, KCC12-3.0, KCC12-4.0, KCC12-5.0, KCC12-6.0

    KCC21-1.0, KCC21-1.5, KCC21-2.0, KCC21-2.5, KCC21-3.0, KCC21-4.0, KCC21-5.0, KCC21-6.0

    KCC22-1.0, KCC22-1.5, KCC22-2.0, KCC22-2.5, KCC22-3.0, KCC22-4.0, KCC22-5.0, KCC22-6.0)

    Type D (KCD11-1.0, KCD11-1.5, KCD11-2.0, KCD11-2.5, KCD11-3.0, KCD11-4.0, KCD11-5.0, KCD11-6.0

    KCD12-1.0, KCD12-1.5, KCD12-2.0, KCD12-2.5, KCD12-3.0, KCD12-4.0, KCD12-5.0, KCD12-6.0

    KCD21-1.0, KCD21-1.5, KCD21-2.0, KCD21-2.5, KCD21-3.0, KCD21-4.0, KCD21-5.0, KCD21-6.0

    KCD22-1.0, KCD22-1.5, KCD22-2.0, KCD22-2.5, KCD22-3.0, KCD22-4.0, KCD22-5.0, KCD22-6.0) Type E (KCE1-2.5, KCE1-3.0, KCE1-4.0)

    Instructions for use

    1. This product should be operated and used by trained medical personnel.

    2. Choose a product that meets the specifications according to the patient's weight.

    3. Before use, check if the packaging is intact, open the packaging from the tear opening, and take the product out of the packaging, being careful to prevent contamination of the tube.

    4. Use a syringe to inject the recommended maximum inflation volume of gas into the airbag from the one-way valve, and check the air tightness of the airbag.

    5. Before inserting the laryngeal mask, use a syringe to completely evacuate the air from the airbag, making the airbag spoon-shaped for easier insertion with a smaller volume.

    6. Just before insertion, lubricate the rear surface of the laryngeal mask and ventilation tube.

    7. The patient should be in a supine position, and the medical personnel should stand behind or to the side of the patient's head, open the patient's mouth, clear the oral and pharyngeal secretions, and adjust the head to a neutral position.

    8. Hold the connection between the airbag and the ventilation tube between your index finger and thumb, with the printed marking line of the ventilation tube facing the patient's upper lip, press the top of the airbag against the hard palate and expand it, inserting your index finger deep into the mouth to advance the mask while maintaining pressure against the upper jaw.

    9. Maintain the curvature of the neck and the extension of the head, press the airbag to advance it along the pharyngeal curve, and the airbag must remain flat to avoid embedding in the tongue, epiglottis, and glottis.

    10. Continue to advance the airbag with your index finger, inserting it into the lower pharynx until resistance is felt. At this point, the airbag is fully inserted.

    11. Use a 30-40 cm long tape to secure the laryngeal mask.

    12. Use a syringe to inject air into the mask through the one-way valve, referring to the inflation volume chart, while observing the indicator of the airbag until the appropriate amount is reached.

    13. Connect the breathing device interface to the machine end of the laryngeal mask and begin use.

     

    1

Phone:0731-52326039
Email:xjingjie@xjingjie.com.cn
         hndee@hndee.com.cn
Address: No. 31 Dongfeng Road, Xiangtan Economic Development Zone, Innovation and Entrepreneurship Center, Building 12, 4th Floor

Key words:

Single-use laryngeal mask airway catheter

Product Consulting

We will contact you within one working day. Please pay attention to your email.

Submission

Contact Us

img 15961010308

Phone:0731-52326039
Email:xjingjie@xjingjie.com.cn
         hndee@hndee.com.cn
Address: No. 31 Dongfeng Road, Xiangtan Economic Development Zone, Innovation and Entrepreneurship Center, Building 12, 4th Floor