undefined
+
  • undefined

Single-use bronchial intubation (occluder)

The operation is simple, with a high success rate for intubation and minimal damage. It can replace double-lumen bronchial intubation, with intubation and cuff positioning times being faster than double-lumen bronchial intubation, reducing airway injury. It can also be used in conjunction with tracheal intubation, laryngeal masks, and various other intubation methods.

  • Commodity name: Single-use bronchial intubation (occluder)

Key words:

Consulting>>
  • Description
  • Product Performance and Advantages

    ▪ Suitable for thoracic surgery, difficult airway, and orthopedic combined thoracic surgery that require single-lung ventilation during open-chest surgery.

    ▪ Simple operation, high success rate of intubation, and minimal injury. Can replace double-lumen bronchial intubation, with faster intubation and cuff positioning time compared to double-lumen bronchial intubation, reducing airway injury, and can also be used in conjunction with tracheal intubation, laryngeal masks, and other types of intubation.

    ▪ Can selectively block the entire lung and lung lobes. Achieves single-lung ventilation without distinction between left and right, and after completing single-lung ventilation, there is no need to replace the single-lumen intubation, avoiding secondary intubation injury.

    ▪ Can provide good lung collapse.

    ▪ Can improve intraoperative hypoxemia (selective lung lobe blockage).

    ▪ Easy to adjust after displacement. Medical silicone cuff, minimal damage to bronchial mucosa, blue appearance for easy identification.

    1

    Product Specifications and Dimensions

    Model

    Maximum Inflation Volume

    Outer Diameter (OD)

    Length (L)

    Cuff Diameter

    09

    4.5ml

    3.0±0.5

    550±50

    14±6mm

    07

    3.0ml

    2.2±0.5

    550±50

    11±6mm

    05

    2.0ml

    1.67±0.5

    550±50

    8±5mm

Phone:0731-52326039
Email:xjingjie@xjingjie.com.cn
         hndee@hndee.com.cn
Address: No. 31 Dongfeng Road, Xiangtan Economic Development Zone, Innovation and Entrepreneurship Center, Building 12, 4th Floor

Key words:

Single-use bronchial intubation (occluder)

Product Consulting

We will contact you within one working day. Please pay attention to your email.

Submission

Contact Us

img 15961010308

Phone:0731-52326039
Email:xjingjie@xjingjie.com.cn
         hndee@hndee.com.cn
Address: No. 31 Dongfeng Road, Xiangtan Economic Development Zone, Innovation and Entrepreneurship Center, Building 12, 4th Floor